At the time of writing it's 2020 and Covid-19 has a grip on the world. Face masks are in high demand. Along with healthcare professionals, the public are receiving conflicting advice on wearing masks to go about their day to day business. But how do we know what masks are suitable for different environments? Here's Dental Sky's guide to face masks!
What are the Different Types of Face Masks?
The first step in identifying the face mask to fit your requirements is to know the different types. Medical face masks are broken down into 2 main categories; surgical masks and respirators. Here are some types of masks you might have heard of:
- Type I Face Masks
- Type I R Face Masks
- Type II Face Masks
- Type II R Face Masks
- FFP2 Face Masks
- FFP3 Face Masks
- N95 Face Masks
- KN95 Face Masks
What's the difference between Type I and Type II Masks?
Type I, and Type I R face masks have a BFE (bacterial filtration efficiency) of 95%, whereas Type II and Type II R face masks have a BFE of 98%. The breathing resistance for Type I R and Type II R masks, are exactly the same as the standard types with the 'R' simply denoting that they are also splash resistant.
Type I, I R, II and II R face masks are medical masks tested in the direction of exhalation (inside to outside) and take into account the efficiency of bacterial filtration. Surgical masks of this type help stop the wearer from infecting the surrounding environment. They are not effective at protecting the wearer from airborne viruses such as Coronavirus.
What is a Type II Face Mask?
Type II face masks (EN14683) are medical face masks made up of a protective 3 ply construction that prevents large particles from reaching the patient or working surfaces, however they are not effective when blood or bodily fluids are present.
Characteristics of Type II face masks include:
- Pleat style with ear loops or ties
- Protective three-layer construction
- Available in a variety of colours and styles
What is a Type IIR Face Mask?
Type IIR face masks EN14683 are medical face masks made up of a 3 ply construction that prevents large particles from reaching the patient or working surfaces. Type IIR Face masks include a splash resistant layer to protect against blood and other bodily fluids. Type IIR face masks are tested in the direction of exhalation (inside to outside) and take into account the efficiency of bacterial filtration.
Characteristics of Type IIR face masks include:
- Pleat style with ear loops or ties
- Protective three-layer construction
- Available in a variety of colours and styles
- Splash resistant layer against bodily fluids
Type I, Type IR, Type II and Type IIR masks are for use in protecting others from the wearer transmitting infection.
What's the difference between FFP2 & FFP3 Face Masks?
FFP2 & FFP3 Face Masks are European classes of respirators, tested on the direction of inhalation (outside to inside) and take into account leakage to the face and filtration efficiency.
FFP2 face masks are the equivalent of N95 face masks, which meet the guidelines from The World Health Organisation for protection against Covid-19. FFP2 masks have a minimum of 94% filtration percentage and a maximum of 8% leakage to the inside. These masks are held tightly in place by the elastic earloop or head strap and have a typical lifespan of 3-8 hours depending on environmental factors.
FFP3 face masks are the most effective at filtration, with a minimum filtration of 99% and a maximum leakage of 2% to the inside. These masks are shaped to your face for a tight fit and some types have a valve to help breathe as the filtration material is thicker. The valve also reduces the build up of moisture, lengthening the lifespan of the mask. FFP3 masks are typically used for handling asbestos.
FFP2, FFP3, N95 and other respirator masks are effective at protecting the wearer from viral transmission.
It should be noted that N95 and KN95 masks can not normally be officially legally recommended for use in Europe although in the current situation with PPE shortages in practice a more flexible approach seems to be being taken with N95 masks.
What are the US and European Standards for Face Masks?
Medical masks and respirators undergo different standards and regulations, dependent on the geographical area in which they are intended to be used.
Medical masks in Europe must comply with the European standard EN 14683, which has 2 levels for bacterial filtration efficiency (BFE) and one level for splash resistance (BFE1, BFE2 and Type R). In the US medical masks must comply with ASTM standards, which have three levels of protection (from low risk of exposure to fluids to high risk of exposure to fluids).
Respirators in Europe must meet European standard EN 149: 2001, which includes three classes of disposable particulate respirators (FFP1, FFP2 and FFP3).
In the US respirators must comply with NIOSH (National Institute for Occupational Safety and Health) standards.
Within this standard, there are several classes of respirators depending on the degree of oil resistance:
- Class N: no oil resistance. A distinction is made between N95, N99 and N100. The number after the letter indicates the percentage of filtration of suspended particles.
- Class R: mask resistant to oil for up to eight hours. Here again, a distinction is made between R95, R99 and R100.
- Class P: a completely oil-resistant mask. There are also P95, P99 and P100.
What are KN95 Masks?
KN95 is the Chinese standard for respirator masks.
According to mask manufacturer 3M, “it is reasonable to consider” China’s KN95s as equivalent to US N95s. Mask standards for Australia (P2), Korea (KMOEL), and Japan (DS) are also highly similar. KN95 masks are rated to capture 95% of 0.3 micron particles in the same way as N95 masks but they have a slightly lower requirement for pressure drop when inhaling and exhaling so will be less 'breathable'. KN95s are also required to be fit tested on humans to demonstrate ≤ 8% leakage.
KN95 masks can not be officially legally recommended for medical use in Europe and in addition The Health and Safety Executive have issued warnings and recommendations on KN95 use due to the substantial amount on the market with fake or false paperwork.
What is Fit Testing?
Fit testing is required for FFP2 and FFP3 respirator masks. When respirator masks are used, they must be able to provide adequate protection for individual wearers. Respirators can't properly protect the wearer if they leak. A major cause of leaks is poor fit – tight-fitting masks need to fit the wearer’s face to be effective.
As peoples' faces come in all shapes and sizes it's not likely that one particular type or size of respirator mask will fit everyone. Fit testing ensures that the mask selected is suitable for the wearer.
Fit testing involves the use of a special kit which establishes a taste test - If you can taste through the mask then the seal is not adequate. Fit testing has to be conducted by a competent person who is appropriately trained, qualified and experienced.
Find out more about Fit Testing here.
Are Homemade Masks Effective?
During the current pandemic there has been a rise in the use of homemade masks and face coverings. Official advice has been evolving throughout with a few schools of thought.
The argument that's being made for their use by The European Centre for Disease Prevention and Control among others is that they could help to limit transmission of the virus in busy public situations where social distancing is difficult, such as public transport or supermarkets.
The argument against their use is that homemade masks will be many times less effective than medical masks at preventing the wearer from transmitting the virus and of almost no use in protecting the wearer themselves. In fact the concern is that a sense of false confidence given by using a mask would lead to a greater risk.
The advice of the UK government is now for the public to wear masks or face coverings in certain circumstances.
The Scottish government recommends people wear them when in shops and on public transport.
The government for England says:
- People should wear face coverings on public transport and in some shops and other "enclosed spaces where social distancing is not always possible.
- From 24th July this is being expanded to require face coverings to be worn in shops.
At the time of writing the advice in Wales has not changed and face coverings have not yet been recommended for the public.
In Northern Ireland people have been told to consider wearing face coverings if they are in places where they cannot social distance.
Members of the public who wish to use surgical or respirator masks masks should be aware that healthcare professionals have been finding PPE hard to source. At an early stage there was a question of whether the public could be depriving healthcare workers who need PPE more of invaluable protection and in turn driving NHS procurement costs up. At present availability of surgical face masks has improved and the prices appear to be coming down.
Members of the public who wish to use cloth face coverings or homemade masks should be aware of their limitations and that social distancing, hand hygiene and avoiding touching the mask or face are also extremely important.
What are signs of counterfeit Face Masks?
The CDC has advised the following on counterfeit respirators:
"NIOSH-approved respirators have an approval label on or within the packaging of the respirator (i.e. on the box itself and/or within the users’ instructions). Additionally, an abbreviated approval is on the FFR itself. You can verify the approval number on the NIOSH Certified Equipment List (CEL) or the NIOSH Trusted-Source page to determine if the respirator has been approved by NIOSH. NIOSH-approved FFRs will always have one the following designations: N95, N99, N100, R95, R99, R100, P95, P99, P100."
Signs that a respirator may be counterfeit:
- No markings at all on the filtering facepiece respirator
- No approval (TC) number on filtering facepiece respirator or headband
- No NIOSH markings
- NIOSH spelled incorrectly
- Presence of decorative fabric or other decorative add-ons (e.g., sequins)
- Claims for the approval for children (NIOSH does not approve any type of respiratory protection for children)
- Filtering facepiece respirator has ear loops instead of headbands
For more information on potential counterfeit NIOSH approved respirators click here.
The European Safety Federation has advised the following on suspicious certificates for PPE, including FFP2 and FFP3 face masks:
"Unfortunately, we (the European Safety Federation = trade association of suppliers of PPE) are informed by different sources about ‘certificates’ or other documents used as a basis for CE marking of PPE (including FFP2/FFP3 masks and eye protection), while these ‘certificates’ have no legal value and can not be used as conclusion of conformity assessment. It is not clear if these documents have actually been issued by the organisations mentioned themselves or if they are fake (we have the impression that a lot of fake documents are being presented as proof of compliance). ESF is not accusing them of doing so, we only want to inform and warn about these documents. "
For more information on suspicious certificates for PPE click here.
When buying surgical masks or respirator masks for a healthcare setting it's important to use trusted suppliers who are able to give you copies of the relevant certification.